How to inspect a Cardiac Science Powerheart G5

The monthly check, step by step: the readiness light, the pads and battery dates, and the serial number that tells you how old it is. Made by Cardiac Science, now part of ZOLL.

By the Think Health team, AED suppliers · Updated

Cardiac Science Powerheart G5 AED

The Powerheart G5 check in six steps

  1. Readiness light: green.
  2. Serial number: readable, and tells you how old the unit is.
  3. Pads expiry: the date has not passed.
  4. Battery date: the date has not passed.
  5. Battery fitted: pushed fully in and flush.
  6. Pads connected: plugged into the AED.

Is this your AED?

Orange and upright, with a round Rescue Ready light by the handle. The model name is printed on the front of the unit and on the label at the back.

1. Is it ready? Check the readiness light

Every AED tests itself and shows the result on a readiness indicator. On the Powerheart G5 it is the round Rescue Ready light beside the handle, with the lid closed.

  • Ready: Green.
  • Not ready: Red means it needs attention. The AED may also beep.

Touching or opening the lid can turn the light red for about five seconds. Leave it alone for a moment, then look again.

See what the light means on other models in our status light guide.

2. Find the serial number

The number beside “SN”, on the label on the back of the AED.

How old is your Powerheart G5?

The serial number carries no date. The manufacture date is printed beside the factory symbol on the same label.

Age matters: many AED owners plan to replace a unit at around ten years, and an older unit may no longer be supported by its maker. More in how old is my AED.

3. Check the pads expiry date

In the small expiry window on the front of the lid.

Replace the pads if the date has passed, after any use (they are single-use), or if the package is open or damaged. Expired pads can dry out and may not stick or conduct properly. More in AED pads expiry.

4. Check the battery date

Lift the battery out of the bottom of the AED and read its label, then press it back until it clicks.

The label shows the date the battery was made, not an expiry date.

More in AED battery expiry.

5. Make sure the battery is fitted

Turn the AED over: the battery should be pushed fully in and flush.

6. Make sure the pads are connected

Open the lid and check the pads connector is plugged into its socket. The AED switches on and talks when the lid opens; that’s normal. Close the lid afterwards.

Child pads or key

Keep a spare pack of child (paediatric) pads beside the AED, not plugged in.

The cabinet, rescue kit and emergency sign

  • Cabinet or case: easy to reach, not locked or blocked, and the alarm working if it has one.
  • Rescue kit: gloves, a razor, scissors and a CPR face mask, sealed and with the AED.
  • Emergency contacts sticker: on the AED or its cabinet, with your local emergency number.

If something fails

Many faults take seconds to fix: push the battery fully home, plug the pads back in, close the lid, then check the readiness light again. An expired battery or pads can’t be fixed on the spot and need replacing. The free inspection’s report lists exactly what failed, and you can ask for a quote for the right pads or battery for your Powerheart G5 from the result screen.

Cardiac Science Powerheart G5: common questions

Why is the Rescue Ready light red on my Powerheart G5?

Red means the AED needs attention, often the battery or the pads. If the lid was just touched, wait about five seconds: it can show red briefly. If it stays red, check the battery and pads, and contact your supplier.

Where is the pads expiry date on a Powerheart G5?

In the small expiry window on the front of the lid. You can read it without opening the AED.

How old is my Powerheart G5?

The serial number doesn’t say. Look for the manufacture date beside the factory symbol on the serial label on the back.

Other AED models

All AED models